(1) Vizual tekshirish: Kabel traylari qurilish maydonchasiga kirganda, quyidagi hujjatlar taqdim etilishi kerak: mahsulotning muvofiqlik sertifikati, viloyat yoki shahar sifat nazorati stantsiyasining davriy tekshiruvi hisoboti va tegishli texnik baholash hujjatlari. Kabel tepsisi plitasining qalinligi tegishli talablarga javob berishi kerak. Issiq galvanizli simi tagliklari uchun{3}}qoplama yuzasi bir xil bo'lishi kerak, ortiqcha qizib ketish, kul hosil bo'lishi yoki galvanizlanmagan joylar kabi nuqsonlardan xoli bo'lishi kerak. Elektrostatik chang qoplamasi tekis, silliq, bir xil bo'lishi kerak va qobig'i, pufakchalari yoki suv pufakchalari bo'lmasligi kerak. Kabel tepsining o'zi tekis bo'lishi kerak, burilish yoki deformatsiya bo'lmasligi kerak, ichki devor esa silliq va burmalarsiz bo'lishi kerak. Kabel tepsisi choklarining yuzasi bir xil bo'lishi kerak, to'liq bo'lmagan payvandlar, yoriqlar yoki kuyish- kabi nuqsonlardan xoli bo'lishi kerak.

(2) Kabel tokchalarini o'rnatish joyi: Kabel novdalari gorizontal ravishda yotqizilganda, erdan balandligi odatda 2,5 m dan kam bo'lmasligi kerak. Kabel tovoqlari bir necha qatlamlarga yotqizilganda, issiqlik tarqalishi, parvarishlash va shovqinlarni oldini olish uchun qatlamlar o'rtasida ma'lum masofani saqlash kerak. Kabel trassalari turli quvurlarga parallel ravishda yotqizilganda, aniq masofa tegishli qoidalarga muvofiq bo'lishi kerak. (3) Tayanch va ilmoqlarni o'rnatish
Kabel kanallari uchun tayanchlar va ilmoqlarning sifati amaldagi tegishli texnik standartlarga mos kelishi kerak. Kabel tovoqlari gorizontal ravishda yotqizilganida, qo'llab-quvvatlash oralig'i odatda 1,5 ~ 3 m ni tashkil qiladi. Vertikal yotqizilganda, qattiq oraliq 2 m dan oshmasligi kerak. Ikki qo'shni simi trubkasi tayanchlari orasidagi gorizontal balandlik farqi 10 mm dan oshmasligi kerak va ikkita qo'shni simi tagliklarining vertikal o'rta chizig'ining vertikal og'ishi 20 mm dan oshmasligi kerak.

1. Kabel muhandisligi bo'yicha qo'llab-quvvatlovchi loyiha sifatida kabel laganda maxsus standart ko'rsatmalarga ega emas. Alohida ishlab chiqaruvchilarning texnik xususiyatlari universallikdan mahrum. Shuning uchun loyihalash va tanlash jarayoni har bir past kuchlanish tizimidagi kabellarning turi va miqdoridan kelib chiqqan holda tegishli simi tepsisini oqilona tanlashi kerak.

(1) Determining the Direction: Based on the building layout plan, combined with the installation of air conditioning pipelines and electrical pipelines, ease of maintenance, and the density of cable routes, determine the optimal route for the cable trays. Indoors, cable trays should be installed along the walls, columns, beams, and floors of the building whenever possible. If a utility tunnel is used, the trays should be installed parallel to the pipes on one side or above, and the down conductors and branch lines should be kept away from crossing as much as possible. If no other pipe racks are available, the trays must be erected independently.

(2) Yukni hisoblash: Kabelning og'irligini asosiy simi tepsisining bo'ylama qismidagi birlik uzunligi uchun hisoblang.

(3) Kabel tepsining kengligini aniqlang: Kabellar soni, simi diametri va kabel oralig'iga qarab simi patnisining modelini va texnik xususiyatlarini, qo'llab-quvvatlovchi qo'llarning uzunligini, tayanchlarning uzunligi va oralig'ini, kabel kanalining kengligi va qatlamlari sonini aniqlang.

(4) O'rnatish usulini aniqlang: To'xtatilgan, tik, yon{1}}devor yoki gibrid turlaridan birini tanlab, sayt sharoitiga qarab simi trubasini mahkamlash usulini aniqlang. Ulagichlar va mahkamlagichlar odatda to'plam sifatida taqdim etiladi. Bunga qo'shimcha ravishda, simi tepsisining tuzilishiga ko'ra, tegishli qopqoq plitalarini tanlang.